Releases

2.19.0

  • Attention: The default approach speed is now 50 µm/s (was 10 µm/s before)
  • This update contains a new firmware which will be installed on startup
  • Extraction workflow: retract probe after alignment and before extraction by a configurable distance
  • Usability improvements for the extraction workflow
  • Use HTTPS by default when fetching probe data
  • Adhesion workflow:
    • Add option to record a cell image without cantilever obstruction before approach
    • Image option “Of surface after retraction” now moves to an unbostructed position
  • Add support for FluidFM Nanosyringe precision plus variants
  • Fixed: Disabled buttons in laser alignment when a hardware error occurs
  • Fixed: In rare occasions, microscope refused re-positioning of lens

2.18.0

  • Multiple wash sequences can be created and saved in the wash tool.
  • Add objective to presets.
  • Single Cell Biopsy workflow enhancements:
    • Objectives can be automatically switched using presets.
    • Add medium check to extraction step.
    • Automatically adjust the mirror position for optimal signals when changing from air to liquid and vice versa.
    • Add tool supporting re-localization of biopsied and observed cells.
  • Result export extensions:
    • Support grouping by preset (only for new results).
    • Optionally add the recording timestamp to the image.
  • Add option to change pressure in 1 mbar or 10 mbar increments in pressure tool.

2.17.0

  • Individual workflows can be shown or hidden in the settings.
  • Add a variant of the injection workflow using a constant Z position instead of constant force.
  • Observe workflow supports merging greyscale images using pixel averaging.
  • Plate wells and sample areas are disabled when there is a collision risk.
  • Fixed: Probe plate may get stuck in observation mode after dropping a probe.
  • Single Cell Biopsy workflow enhancements:
    • Insert probe alignment step before extraction.
    • Add option to record a cell image without cantilever obstruction.
    • Add step to rinse the cantilever after dispensing the extract.
  • Add project and experiment filtering.
  • Stage axis disengagements are now reported as error.
  • Annotations in exported images are only shown once for the same point.
  • Improve stability of stage operations in long-term runs.
  • Replaced the “filling help” in the fill probe step with a new video difference tool

2.16.0

  • Single Cell Biopsy workflow supports going back to previously extracted cells
  • Focus level is saved during point selection and optionally restored in observation workflow
  • Add option to export images as .tiff files
  • Add diagnostic data collection (with opt-out option)
  • Fixed: Wash tool not stopping on cancel
  • Fixed: Export from multi-column results view only exporting a single result
  • Fixed: Results in projects with trailing whitespace cannot be exported
  • Fixed: Stage moves into an unexpected direction after performing an infinity drag

2.15.0

  • Add Single Cell Biopsy workflow and volume calculation tool.
    Refer to this forum entry for application details and contact information.
  • Fixed: Observation workflow did not correctly handle observation height parameter
  • Fixed: In seldom cases, probes were erroneously detected as being gripped
  • Fixed: Data export did not run to completion on processing errors

2.14.1

  • Fixed: Stage moves into an unexpected direction after performing an infinity drag

2.14.0

  • Extend injection worfklow with a flushing option
  • Restore probe properties on project continuation
  • User-delayed image recording in observation workflow to allow manual focus override
  • Support fine-tuning of probe-focusing tool
  • Currently active project is visible in the windows’ status bar
  • Fixed: Export all groups did not work in every case
  • Fixed: Positioning errors when operating close to the stage boundaries or returning to them
  • Fixed: Stage was seen as busy although motion completed
  • Fixed: Print from file preview was permanently disabled on error

2.13.0

  • Add option to export images with compression enabled
  • Improve stage dragging accuracy and stability
  • Ability to reconnect on camera connection loss
  • Tool to temporarily override focus limit
  • More prominent indication whether observation mode is enabled
  • Support new camera type
  • Actually reachable area is now consistently shown in all point selection steps
  • New extraction workflow
  • Include tool for flow data fitting
  • Settings to configure how laser and mirror alignment actuators are accessed
  • Fixed: Possible to support multiple lenses with the same magnification
  • Fixed: Preset configurations were sometimes lost when hardware changed

2.12.0

  • Improve reliability of laser and mirror alignment actuators
  • Improve precision of xyz motions
  • Fixed: Spring constant shows error “InvalidOperationException” if fitting failed
  • Fixed: In volume calculator the wrong intensity was used in 2.11 leading to misleading results
  • Fixed: Attenuator changes triggered by MCZ are not noticed by the software