Releases
2.7.0
- New annotation option in exported images allows to trace back injection points
- Accelerate image previews
- Increase responsiveness when displaying point groups
- Support exporting multiple individual files at once (ctrl-click)
- Headers of exported files are now prefixed with a hashtag to simplify parsing
- Creation date of exported files is set to their acquisition timestamp
- Increase robustness in barcode driver implementation
2.6.0
- Already processed points can be visualized in navigation tool and video feed
- Automatic, additional retraction when moving to far-away points
- Automatic recovery of washing sequences
- Faster data loading operations
- Fixed: Applying the same plate type on left and right port caused the content height parameter to be ignored
2.5.0
- Option to recover defined yet unprocessed points
- Automatic, additional retraction when moving to far-away points
- Extend volume calculator to support timelapse-style reporting
2.4.0
- Option to tag plates with names and ability to resume experiment containers.
- Optional retraction of lenses when passing plates.
- Fixed: The system allowed xy positioning that would lead to a crash between nose and well. This has been corrected for the built-in 12 and 24 well plates. Furthermore, the bottom height of the built-in 6 well plate has been corrected as well.
- Fixed: Data manager did not show the last item of a group.
- Fixed: The stiffness computation resulted in too low values. Reason was the erroneous determination of quality factors which were passed on to the spring constant formula. To obtain corrected results simply re-run the computation on the original measurement data.
2.3.0
- Add Volume Calculator to Result Viewer
- Faster image preview
- User interface gives clearer feedback when system is busy
2.2.0
- Add Volume Calculator tool for computation of injected liquids
- Fixed:
Cytosurge Plate Nr. 2
had incorrect height offsets. - Fixed: The software crashed when the stage was being dragged with mouse and touchscreen at the same time.
2.1.0
- New Cell Isolation workflow
- Extend ‘Print from File’ workflow to use a new file format thats adds more instruction types and supports more parameters
- Add simplified preparation workflow without calibration steps
- Add setting that controls whether to store spectroscopy curves of injection runs
- Reduce overshoot in approach scenarios
2.0.8
- Improve data handling to support large data sets
- Unify data visualization and export capabilities of control software and data viewing tool
- Improve reliability of startup and shutdown procedure
- Fixed: In rare cases stage dragging was erroneously forbidden or caused runtime errors
- Fixed: Some dialogs were kept open despite close request